Isolate Extracellular Vesicles in 15 Minutes with IZON qEV Columns

Blog Post

Illustration of the IZON qEV column range for size exclusion chromatography, in different sizes from smallest to largest, for isolating extracellular vesicles
Wednesday, January 20, 2016

Article published in 2016, updated in November 2026 with the new qEV Gen 2 range.

Izon Science qEV size exclusion columns are one of the easiest and fastest methods for isolating extracellular vesicles (EVs) from cell culture supernatants and complex biological fluids such as plasma, serum, urine, milk and cerebrospinal fluid. Unlike ultracentrifugation or precipitation kits, size exclusion chromatography (SEC) does not significantly alter the sample: separation occurs under gravity, without high centrifugal forces or precipitating reagents. Isolated vesicles remain intact and biologically active, with a reduced risk of protein or vesicle aggregates.

Advantages of qEV size exclusion columns
  • Speed: approximately 15 minutes to separate extracellular vesicles with the qEVoriginal column (times vary depending on the column format).
  • Purity: Gen 2 columns in the 35 nm and 70 nm series remove approximately 99% of contaminating proteins.
  • Lipoprotein removal: significant, and highest with the 70 nm series, which is particularly useful for plasma samples.
  • Physiological conditions: buffers with physiological osmolarity can be used.
  • Reusable: each column can be used up to five times, with a cleaning step between uses.
What has changed since 2016: qEV Gen 2 columns

Since this article was first published, qEV technology has evolved significantly. The original columns, now referred to as “Legacy”, have been replaced by the Gen 2 range, which uses an exclusive agarose resin developed specifically for extracellular vesicles. The result is a sharper separation between EVs and soluble proteins, and therefore purer isolates for downstream analysis (proteomics, microRNA sequencing, functional studies).

Anyone using protocols developed with the older Legacy columns should revalidate them, as elution profiles may differ with the new resin.

A column for every sample volume

In 2016 the choice was limited to a few formats. Today the qEV range covers volumes from a few microlitres up to industrial scale:

Column Sample loading volume
qEVsingle 150 µL
qEVoriginal 500 µL
qEV1 1 mL
qEV2 2 mL
qEV10 10 mL
qEV100 100 mL

For larger requirements, Izon produces custom columns with volumes reaching several litres.

Three resin series: purity or recovery?

Each format is available in three series, distinguished by the pore size of the resin:

  • 20 nm series (optimal range 20–100 nm): the highest recovery, also suitable for sub-50 nm particles such as exomeres and small viruses.
  • 35 nm series (35–400 nm): a balanced compromise between purity and recovery, widely used for EVs from cell cultures.
  • 70 nm series (70–2000 nm): the highest purity and the greatest lipoprotein removal, ideal for plasma biomarker research.
From manual isolation to automation

Alongside the columns, the qEV platform now includes instruments that make isolation more reproducible and scalable. The Automatic Fraction Collector (AFC) automates fraction collection for routine laboratory use. qEV DXter is a robotic system that processes up to 24 samples in parallel, designed for high sample throughput, for example in diagnostics. qEV Zenco is an automated chromatography system for large-volume columns (qEV2, qEV2 Columns, qEV100 and custom columns). For large-scale production, SEC can be combined with tangential flow filtration (TFF).

Fast and cost-effective

qEV columns are cost-effective, readily available and manufactured under an ISO 13485:2016 certified quality system, ensuring consistent performance across all columns. For those developing diagnostic or therapeutic applications, cGMP-ready columns are also available on request, and the platform has been extended to the purification of lipid nanoparticles (LNPs).

You can spend your time focusing on your research, rather than on isolating extracellular vesicles.

Related products 

SEC column for extracellular vesicle isolation of 150 µL sample loading volumes of biofluids and cell culture media
SEC columns for extracellular vesicle isolation with 500 µL sample volumes.
SEC columns for extracellular vesicle isolation with 1 mL sample volumes
SEC columns for extracellular vesicle isolation with 2 mL sample volumes
qEV10 20nm, 35nm and 70nm
SEC columns for extracellular vesicle isolation with 10 mL sample volumes
qEV100 20nm, 35nm and 70nm
SEC columns for extracellular vesicle isolation with 100 mL sample volumes
The AFC automates extracellular vesicle (EV) isolation and enables precise and reproducible separation.
High-capacity EV and nanoparticle isolation for advanced diagnostic and therapeutic development
The automated chromatography system for purifying samples from qEV2, qEV10, qEV100, and larger customized columns
Efficiently Scale Nanoparticle Purification with qEV Tangential Flow Filtration

Partner 

IZON Science